    HIGHLIGHTS

    • Multifunctional test device
    • Relay Timing Tests
    • Turns Ratio Tests
    • Contact Resistance Tests
    • 3Φ Circuit Breaker Timing Tests

    SUWI-120 series stands as a versatile testing instrument meticulously crafted to evaluate the performance of power and control apparatus within substations. It encompasses an array of essential tests, including the precise assessment of Relay Timing, the determination of a Transformer's Turns Ratio, the scrutiny of Circuit Breaker Contact Resistance and Timing, as well as the examination of MCBs, among other critical functions. This all-encompassing substation testing device has earned the name SUWI, from our belief in its skills as a Substation Wizard.

    RELAY TIMING MEASUREMENT

    The SUWI instrument can automatically test over-current, over-voltage, directional overcurrent relays and frequency control relays. SUWI has an adjustable output current up to 110A AC / 120A DC and an adjustable output voltage to 150V AC / 220V DC. It has four universal input modules.

    TURNS RATIO MEASUREMENT

    Employing elements of performance tests specified in the ANSI/IEEE C57.12.90 standard, the instrument performs transformer ratio measurements to a precision of 0.08 % across a ratio range of 0.8 to 10,000. SUWI also measures phase angle and polarity, and it can generate 1V, 4V, 10V, 40V and 100V AC test voltages to facilitate the measurement of turns ratio for current, voltage and power transformers.

    CONTACT RESISTANCE / LOW RESISTANCE MEASUREMENT

    SUWI has an adjustable output DC current up to 120 Amps which facilitates the measurement of contact resistance of a circuit breaker, a shunt or disconnector. SUWI-120 can measure resistance up to 5 Ω, with a resolution of 0.01μΩ.

    CIRCUIT BREAKER TIMING

    Contact Timing Tests are performed to determine a breaker's contact performance against its manufactured specifications. The timing for a breaker's operation such as OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN and OPEN-CLOSE-OPEN are measured for all three-phases simultaneously. SUWI can perform 3-phase circuit breaker timing test cycles as described above along with coil current measurements using internal and external trigger inputs.

    TECHNICAL SPECIFICATIONS

    Measurement Parameters Relay Timing Tests (over current relays, over voltage relays, directional over current relays, frequency control relays);
    Turns Ratio Measurement, Phase Angle, Polarity, Ratio Error (%);
    Contact Resistance/Low Resistance Tests (Circuit breaker contact resistance and shunt resistance)
    Circuit breaker timing test (3-phase circuit breaker timing tests; open, close, open-close, close-open, open-close-open timings, coil current measurement, internal and external trigger operations)
    PROTECTION RELAY TIMING MEASUREMENT FEATURES
    Current Outputs Up To 110 A AC (magnitude and frequency adjustable)
    Up to 120 A DC
    Voltage Outputs 150 V AC (magnitude and frequency adjustable)
    220 V DC
    Universal Input Modules 4 input module; Binary wet/dry
    Up to 300 V AC/DC voltage measurement
    TURNS RATIO MEASUREMENT FEATURES
    Ratio Measurement Modes CT Mode

    PT Mode (Single-Phase and Three-Phase)

     
    Test Voltages CT Mode: 1 V and 4 V ;
      PT Mode: 1, 4, 10, 40 & 100 V
    Ratio Range 0.8 – 10,000
    CONTACT RESISTANCE/LOW RESISTANCE MEASUREMENT FEATURES
    Measurement Modes Static Resistance Measurement
    Auto Test Mode Yes
    Test Current Up to 120 A DC
    Measurement Range Up to 5 Ω
    CIRCUIT BREAKER TIMING MEASUREMENT FEATURES
    Measurement Parameters Contact Timing (O, C, O-C, C-O & O-C-O); Coil Current Measurement, Internal and External Trigger Operations
    Timing Windows 1s, 10s, 20s
    Timing Accuracy 0.05% rdg ± 0.1 ms
    Contact detection Yes
    Trigger input voltage 24 – 300 V DC or ACpeak
    Breaker Initiate Capacity 20 A, 300 V DC or ACpeak
    Initiate current reading range 0 – 20A DC, 5 kHz
    GENERAL FEATURES
    Power Supply 100-240 V, 47/63 Hz,
    Internal Memory Yes
    Communication USB 2.0/1.1 Standard-B, Ethernet
    PC Software DMP Software
    Display 7-inch IPS 1024×600 pixel touch panel display
    Dimensions (16.9 × 12.9 × 9.3)" (429 x 328 x 236) mm
    Weight 10.70 kg
    Temperature Working : -10 °C to +60 °C; Storage: -30 °C to +70 °C
    Humidity 95% RH Non-condensing
    Protection Class IP67 (case lid closed)
    Included in the Package 5x5m Input Cables (Red), 5x 5m Input Cables (Black), 2x 3m Contact Cable (White), 2x 3m Contact Cable (Blue), 1x 2.5m Current Cable (Red), 1x 2.5m Current Cable (Black), Power Cable, Ground Cable, USB Cable, Ethernet Cable, USB flash drive, Instruction Manual (Soft Copy), DMP Software, Cable Bag
    Optional 5m Measurement Cable Set for TURA-01 , TURA01 Cable Set Adapter, CIBREL3 Cable Set Adapter, 6m Contact Cable Set of contact 1 , 2 &3